Expansion Joint Devices AQUASTOP Type DSHO – 0 – ANG/060

Expansion Joint Device AQUASTOP DSHO – 0-ANG/060 is a 3-meter long overlay expansion joint. This device is suitable for both indoor spaces and open areas. Engineered for angular connections (wall-floor, wall-ceiling) in critical structures. Reduces stresses caused by shrinkage and temperature fluctuations. Withstands light vehicle load.

Displacement, mm

Compression: 12
Tension: 12
Shear: 8

1844,00 

Price/l.m.
loader-icon

Expansion Joint Devices AQUASTOP Type DSHO – 0-ANG/060 – designed for protecting angular joints in horizontal and vertical structures (wall, floor, ceiling joints) in areas with high pedestrian traffic: shopping centers, warehouses, office spaces. Low-intensity light vehicle traffic is permitted. Overlay installation provides simple integration into finish coatings. Joint width — 60 mm. Equipped with a compensator made of thermoplastic elastomer (TPE), which can be easily replaced when worn out.

Technical advantages:

  • Material: aluminum guides (GOST standard), compensator — wear-resistant TPE.
  • Strength: designed for mechanical and operational loads.
  • Corrosion resistance: resistant to moisture, temperature fluctuations, aggressive environments.
  • Durability: aluminum is corrosion-resistant, compensator can be replaced without dismantling the profile.

Installation:

  • Mounting: mechanical overlay installation using anchors or dowels.
  • Additionally: angular design for complex joints (e.g., wall-floor transitions).

Additional information

Compensator Material

TEP

Country of manufacture

Russia

Profile Type

Angular

Installation Type

Surface-mounted

Load - MPa

0,25

A (Joint Width), mm

60

B (Insert Width), mm

120

C (Profile Width), mm

120

Length

3000 mm

Installation Guidelines for AQUASTOP® DSHO Expansion Joint Devices

  1. Preparatory Work:
    • Clean the base surface from dirt, debris, and dust.
    • If necessary, level the base with a polymer-cement mixture or equivalent.
    • Repair defects (cracks, pores, exposed reinforcement).
  2. Temperature Conditions: Perform work at air temperatures between +5°C and +30°C.
  3. Layout and Gaps:
    • Install beacons according to the finished floor level (starting from a reference point near the wall).
    • Leave a damping gap ≤10 mm along the perimeter of the walls.
  4. Device Installation:
    • Assemble the sections, embedding the supporting parts into adhesive/sealant.
    • Join sections with 150 mm staggered seams.
    • ⚠️ Prohibited: Use anchor fasteners.
  5. Additional Operations (if required):
    • Fill gaps with polyurethane sealant.
    • Perform thermal welding of the compensator (185-195°C).
    • Apply primer (composition: specify in the project).
DSHO-24 corner installation diagram
DSHO-24 installation diagram

 

Universal Requirements:
- Compliance with SP 71.13330-2017;
- Check base evenness with a straightedge (tolerance: ≤2 mm longitudinally, ≤1 mm transversely);
- Fastener tightening torque: (specify for particular model);
- All parameters (A, B, C) are determined by the project.

⚠️ Important! For non-standard conditions, consult OOO TD "GYDROMIX".

Download Files for AQUASTOP® DSHO Expansion Joint Devices

PDFDownload Aquastop Product Catalog Part 2: Expansion Joint Devices
PDFDownload AQUASTOP DSHO Device Specifications