Expansion Joint Devices AQUASTOP Type DSHL – 30 – ANG/035

Expansion Joint Device AQUASTOP DSHL-30-ANG/035 is a 3-meter long embedded expansion joint. This device is suitable for both indoor spaces and open areas. Designed for angular connections (wall-to-floor, wall-to-ceiling) in critical structures. Reduces stresses caused by shrinkage and temperature fluctuations. Withstands intensive pedestrian loads.

Displacement, mm

Compression: 15
Tension: 5
Shear: 20

1165,00 

Price/l.m.
loader-icon

Expansion Joint Devices AQUASTOP Type DSHL-30-ANG/035 — designed for protecting corner joints in horizontal and vertical structures (wall, floor, ceiling junctions, transitions between rooms) in areas with high pedestrian traffic: shopping centers, office spaces. Joint width — 35 mm. Suitable for joints in floor structures with thickness — 30 mm. The guides are installed using embedded method. The device consists of perforated aluminum guides and an elastic profiled compensator made of thermoplastic elastomer (TPE) in the center.

Technical advantages:

  • Material: aluminum guides (GOST standard), compensator – wear-resistant TPE.
  • Strength: designed for mechanical and operational loads.
  • Corrosion resistance: resistant to moisture, temperature fluctuations, aggressive environments.
  • Durability: aluminum is corrosion-resistant, compensator can be replaced without dismantling the profile.

Installation:

  • Installation method: embedded, with fixation of guides in concrete base.
  • Mounting: 3-meter long aluminum pressure bars, anchors or dowels.
  • Specifics: angular design for complex junctions (e.g., wall-to-floor transitions).

Additional information

Compensator Material

TEP

Country of manufacture

Russia

Profile Type

Angular

Installation Type

Embedded

Load - MPa

no

A (Joint Width), mm

35

B (Insert Width), mm

40

C (Profile Width), mm

85

Profile Height, mm

30

Length

3000 mm

Installation Guidelines for AQUASTOP® DSHL Expansion Joint Devices

  1. Preparatory Work:
    • Clean the base surface from dirt, debris, and dust.
    • If necessary, level the base with a polymer-cement mixture or equivalent.
    • Repair defects (cracks, pores, exposed reinforcement).
  2. Temperature Conditions: Perform work at air temperatures between +5°C and +30°C.
  3. Layout and Gaps:
    • Install beacons according to the finished floor level (starting from a reference point near the wall).
    • Leave a damping gap ≤10 mm along the perimeter of the walls.
  4. Device Installation:
    • Assemble the sections, embedding the supporting parts into adhesive/sealant.
    • Join sections with 150 mm staggered seams.
    • ⚠️ Prohibited: Use anchor fasteners.
  5. Additional Operations (if required):
    • Fill gaps with polyurethane sealant.
    • Perform thermal welding of the compensator (185-195°C).
    • Apply primer (composition: specify in the project).
DSHL-0 installation diagram DSHL-30 corner installation diagram

 

Universal Requirements:
- Compliance with SP 71.13330-2017;
- Check base evenness with a straightedge (tolerance: ≤2 mm longitudinally, ≤1 mm transversely);
- Fastener tightening torque: (specify for particular model);
- All parameters (A, B, C) are determined by the project.

⚠️ Important! For non-standard conditions, consult OOO TD "GYDROMIX".